本系列产品技术参数高,开断能力强,动作可靠,性能稳定,寿命长,维护简便,且无爆炸危险及污染,供工矿企业,发电厂及变电站作单母线系统电气设施的保护和控制之用,并适用于频繁操作的场所,也可用于切全电容器组等特殊场合。
断路器采用一体化和模块化设计,整体结构简单合理,采用上下布置,灭弧室部分在上面,联锁和操动机构在下面。使用权专用的3AV3弹簧操动机构,无需调整,动作稳定可靠。
真空灭弧室布置在封闭的绝缘筒内,提高了绝缘性能,并缩小了的整体尺寸。
GENERAL
Model ZN86-40.5/(3AV3)Series Indoor AC HV Vacuum Circuit Breaker is suitable for u use in three-phaes 50Hz 40.5KV system to open/close load current.overload current and fault current in factory and mining enterprises,power plants and substations. It's also suitable for use at she places of frequent operations.
结构特点
本断路器采用上下结构,易于检修.复合绝缘结构,有效减小体积,具有性能可靠、使用寿命长、检修方便、免维护的特点。
DESIGN FFATURES
The circuit breaker adopts up-and-down structure, easy for maintenance, Its compound insulation structure effectively reduces its volume.It has she features of reliable performance,long service life,comvenient overhaul and free maintenance.
技术参数TECHNICAL DATA、
序号 | 参 数 名 称 | 单位 | 数 值 |
1 | 额定电压Rated voltage | KV | 40.5 |
2 | 额定电流Rated current | A | 1250 1600 |
3 | 额定短路开断电流 Rated short-circuit breaking current | KA | 25 31.5 |
4 | 动稳定电流(峰值) | KA | 63 80 |
5 | 4S热稳定电流 | KA | 25 31.5 |
6 | 额定短路关合电流(峰值) Rated short-circuit making current(peak) | KA | 63 80 |
7 | 额定短路电流开断次数 | 次 | 20 |
8 | 额定操作顺序 | 分—0.3S—合分—180S—合分 | |
9 | 额定频率 | Hz | 50 |
10 | 额定雷电冲击耐受电压(全波) | KV | 185 |
11 | Lmin工频耐受电压 | KV | 95 |
12 | 合闸时间 | Ms | <=75 |
13 | 分闸时间Natural opening time | Ms | <=60 |
14 | 机械寿命Mechanical life(time) | 次 | 10000 |
15 | 额定电容器组开断电流 | A | 630 |
16 | 额定操作电压 | V |